LCD graphics displayText and mimic diagrams that display modes of operation, system parameters and alarms.10/100 BaseT сonnectionConnect the device to a network using a 10 or 100 BaseT connection.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance.Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.Scalable runtimeAllows additional run time to be quickly added as needed.Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced.Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.Network manageableProvides remote power management of the UPS over the network.InfraStruXure Manager CompatibleEnables centralized management via the APC InfraStruXure Manager.SmartSlotCustomize UPS capabilities with management cards.LED status indicatorsQuickly understand unit and power status with visual indicators.Serial connectivityProvides management of the UPS via a serial port.Plug-and-Play external batteriesEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.Rack/Tower convertibleProtects the initial investment in the UPS when migrating from tower to rack-mount environment.Flash upgradeable firmwareInstall maintenance releases of firmware remotely using FTP.User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.Disconnected battery notificationWarns when a battery is not available to provide backup power.Audible alarmsProvides notification of changing utility power and UPS power conditions.Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.Cold-start capableProvides temporary battery power when the utility power is out.Resettable circuit breakerEasy recovery from overloads; no need to replace a fuse.
Спецификации
- Изх. мощност, VA4500 watt / 5000 VA
- ТехнологияOn-line
- Гаранция, месеци24 месеца
- Входно напрежение230 V (220 V, 240 V user selectable)
- Изходно напрежениеAC 230 V ± 3% - 50/60 Hz
- Брой изводи10
- Тип изводи(6) IEC 320 C13, (4) IEC 320 C19, (2) IEC Jumpers
- Интерфейси1 x serial - RJ-45 1 x management (USB) - 4 pin USB Type B 1 x EPO (emergency power off)
- Защити-
- Защита от пренапрежениеДа
- Форма на изходното напрежениеSinewave
- ДругиMaintenance free, sealed, leak-proof
- ЦвятBlack
- Дълбочина71.9 cm
- Височина13 cm
- Ширина43.2 cm
- Тегло54.55 kg
- Време за зареждане3 hours